Written by: Jake Evans

Which way do you run the streets to maximize solar exposure for dense Net Zero development?

A street view of a row of colorful houses. The center blue house is a Net Zero house designed by Powerhouse Designs and built by TC Legend Homes.

Common wisdom states that the optimal streets run east west, which makes sense if you’re the house on the north side of the street, because there’s nothing shading your house, garden or solar panels. However, living on the south side of the street, you suffer from north facing gardens and probably some shading unless the lots are 5000sf or greater.

Critically, 10 dwelling units (du) per acre is the density with enough inhabitants to support a bus service (*1), a key part of the sustainable urbanist vision for transit, pedestrian & bike use, rather than private cars. An acre is 43500sf.

My conclusion is that the common wisdom is wrong for dense, Net Zero development, that the streets should run north-south.

A Net-Zero house has most of the windows on the south side of the house because south facing windows can be effectively shaded from summertime overheating, and can harvest wintertime solar energy.

Because all the windows are on the south walls, we can’t have another 2-story house immediately to the south as shown in ‘East-West 3700’ below, or the valuable direct wintertime sunlight will be prevented from entering & you’ll have a house that is gloomy all winter.

Sure, if the lots are big, we can keep the southern house away, as shown in ‘East-West 4500’ below, but then we end up with less than 10 du/ acre (du/a) and there’s no bus & everyone’s driving cars.

The ‘North-South 3800’ drawing below shows a 1-story neighbor garage to the south, avoiding shade. Bingo! That’s a 3800sf lot, and offers 11.34 du/a. Additionally the frontage length is reduced which lowers roadway & utility development costs.

Street Orientation Option 1 North-South 3800. A drawing showing a block of houses on streets oriented north to south and situated on their lots with garages on the north side and the long side of the house on the north and south side, allowing solar gain on the south side while not being blocked by the roofline of the neighboring house. Text says "2000 sf house with dbl garage. 3835 sf lot. 59' frontage / du = 11.34, du/a = density supports bus OK. Winter light = 100%. Equal solar exposure for all houses."
Street Orientation Option 2 East-West 3700. A drawing showing a block of houses on streets oriented east to west and situated on their lots with garages to one side of the house and the long side of the house on the north and south side. The two houses to the north of the block have garages on the west side and the southern two houses have garages on the east side mimicking the layout. The orientation allows solar gain on the south side but the diagram shows that 40% of the northern houses will be blocked by the roofline of the neighboring southern house. Text says "2000 sf house with dbl garage. 3700 sf lot. 74' frontage / du = 11.76, du/a = density supports bus OK. Winter light = 60% @ northern houses."
Street Orientation Option 3 East-West 4500. A drawing showing a block of houses on streets oriented east to west and situated on their lots with garages to one side of the house and the long side of the house on the north and south side. The two houses to the north of the block have garages on the west side and the southern two houses have garages on the east side mimicking the layout. The orientation allows solar gain on the south side while not being blocked by the roofline of the neighboring southern house. However the houses are visibly farther apart. Text says "2000 sf house with dbl garage. 4505 sf lot. 74' frontage / du = 9.66, du/a = density ~ supports bus OK. Winter light = 100%."

(*1) Transit modes related to residential density (Boris Pushkarev & Jeffry M Zupan)

Related Posts

Lynden Powerhouse Open House Tour with Sustainable Connections

Lynden Powerhouse Open House Tour with Sustainable Connections

Lynden Powerhouse Open House Tour with Sustainable Connections Written by: Nicole Miller Sustainable, innovative and efficient! A couple weeks ago we were pleased to host a home tour of the Lynden Powerhouse project in conjunction with Sustainable Connections and with...

Case Study & 2024 HIA Winner: The Lynden Powerhouse

Case Study & 2024 HIA Winner: The Lynden Powerhouse

Case Study & 2024 HIA Winner: The Lynden Powerhouse Written by: Talia Dreicer, Nicole Miller & Senna Scott The Lynden Powerhouse Case Study, written by Talia Dreicer, was featured in this season's Master Builders Association Publication! "The Lynden Powerhouse...

Net Zero Energy Co-Housing

Net Zero Energy Co-Housing

Net Zero Energy Co-Housing Written by: Nicole Miller We are excited to announce our Net Zero Energy Co-Housing spec project that’s currentlyunder construction! Titled “Woburn House” on our social media, this 5-bedroom home isintended to house multiple family units and...

Zero-Energy Building Fan?

Sign up for TC Legend updates.